Businesses fitting out a new space
Cooling planned alongside the fit-out, with routes and plant positions agreed before ceilings and walls close up.
System design & site surveys
A free site survey and a written specification that says which units go where, why they were chosen and what the installation involves — so the system holds temperature on the hottest afternoon instead of running flat out and never getting there.
Free surveys · Quotations same or next working day · Multi-brand, no manufacturer tie-in
Multi-brand
Air conditioning, ventilation and cellar cooling, any major brand
F-Gas + REFCOM
Certified and registered refrigerant handling
1–2 hours
Emergency breakdown response, depending on location
3 years
Labour warranty, plus 3-year parts cover
Up to £1m
Public liability insurance, RAMS on request
Sizing air conditioning is not a matter of picking a kilowatt figure off a chart. It is the room volume, the glazing and which way it faces, the insulation, how many people are in the space and when, the heat given off by equipment, and how often doors open. Get that wrong on the low side and the system runs continuously and never reaches setpoint; get it wrong on the high side and it short-cycles, dehumidifies badly and costs more than it needed to.
We survey free of charge across Welshpool, Shrewsbury, Oswestry, Newtown and the surrounding mid-Wales and Shropshire area, and return a free written quotation the same or the following working day depending on the size of the job.
Because we are not tied to a single manufacturer's accreditation scheme, the design is driven by the building rather than by whichever brand we are signed up to. That applies to indoor unit type, outdoor unit siting, pipe routing, condensate strategy and electrical supply.
Cooling planned alongside the fit-out, with routes and plant positions agreed before ceilings and walls close up.
Specifications and options across a portfolio, with RAMS on request and consistent kit choices between sites.
A contractor who will attend the site, mark up routes and give a specification your programme can actually be built around.
Equipment heat load calculated properly, with resilience and continuous running designed in from the start.
Extensions, loft conversions and garden rooms designed around the actual load and the routes available in the building.
A second survey and an independent specification, so you can see whether what you were quoted was sized on evidence or on a guess.
The cost of leaving it
Almost every system we are called to that 'never really worked' was decided before anyone measured anything. Someone picked a unit off a price list, someone else agreed a position because it was the easiest place to drill, and the building was never assessed at all.
Undersized systems run permanently at full output and still leave the room warm on the days you actually needed them. Oversized systems cycle on and off, leave the air clammy, wear their components out faster and cost more to buy. Badly sited outdoor units recirculate their own hot air, lose efficiency and land noise on the wrong window.
None of that can be fixed afterwards without ripping work out. It is decided at survey — which is exactly why the survey is free and why we would rather spend an hour in the building than quote from a floor plan.
The system runs flat out on the hottest afternoon and never reaches setpoint — the day you bought it for.
Short-cycling, poor dehumidification, faster component wear and money spent on capacity you never use.
Enclosed corners recirculate hot air and cut efficiency, and noise lands on a neighbour's window instead of a blank wall.
Runs that could have been end up surface-mounted, and drainage that should fall naturally ends up on a pump.
Finding out the supply will not carry the plant after the kit has been ordered delays the whole job.
Works that were never programmed around trading hours cost you the trade the system was supposed to protect.
Our process
We come to the building, walk the spaces and talk through how they are actually used — not how a drawing says they are used.
Room volumes, glazing and orientation, insulation, occupancy and equipment load are measured and counted so capacity is based on evidence.
Wall-mounted, cassette, ducted, multi-split or VRV/VRF chosen against the ceiling, structure and layout, with indoor positions marked up.
Refrigerant runs, condensate falls and outdoor unit locations planned for airflow, noise and access — before anyone drills anything.
Supply capacity, isolation, working at height and site access confirmed, with RAMS issued on request for inductions.
A specification you can hold a contractor to: what goes where, what the kit is, what the works involve and what it costs — same or next working day.
Phasing, out-of-hours working and access agreed in advance so the installation fits around your trading hours.
What you get
No charge to have the building assessed and no charge for the written specification that comes back.
Heat load assessed properly, so the system holds temperature rather than chasing it.
No accreditation scheme dictating the kit. We specify what suits the building, the budget and the running costs.
A written spec makes it obvious whether two quotes are for the same system or two very different ones.
Quotations come back quickly, sized to the job, so your programme is not waiting on us.
Routes, positions, drainage and supply resolved at design stage, which is what keeps installations tidy and on programme.
Risk assessments and method statements provided for site inductions, facilities teams and main contractors.
The people who design it install it, commission it and maintain it — so nobody can blame the last party involved.
In detail
A specification is a series of trade-offs. Here is what sits behind each of them, so you can read a quote and understand what you are being offered.
Load comes from the fabric (glazing, orientation, insulation, roof), the occupancy (how many people, for how long) and the equipment (IT, kitchen, machinery, lighting). Each is counted rather than estimated as a lump.
The output is a capacity figure per space, which is what unit selection is then built on. Without it, everything downstream is a guess.
Wall-mounted units are quick, cost-effective and ideal for single rooms. Cassettes distribute air far more evenly across open-plan floors but need ceiling void depth and a condensate route. Ducted units hide everything except the grilles, which suits design-sensitive and listed interiors but is the most involved to install.
The building usually makes this decision. Void depth, structure, ceiling type and how the space is used matter more than preference.
One outdoor unit per indoor unit is simplest. Multi-splits serve several indoor units from one condenser and save external space, which often decides it on high-street and terraced properties. VRV/VRF serves many zones from modular plant, varies flow to demand and scales for future floors.
Line lengths and level differences affect performance on multi-splits and VRF, which is survey work — not something to resolve on installation day.
Condensers need free airflow, service access, a solid mounting and a position where noise does not land somewhere sensitive. Enclosed corners that recirculate hot air are the most common avoidable mistake we find.
Roof platforms, wall brackets and ground frames each carry their own access, weight and noise considerations, and are chosen at survey.
Refrigerant routes are planned to be as short, as direct and as concealed as the building allows. Condensate is best run on natural fall; lift pumps are used where the layout leaves no alternative, not as a default.
Deciding this at survey is why installations end up tidy. Deciding it on the day is why some do not.
Nearly everything we specify is a heat pump, delivering several units of heat per unit of electricity in reverse cycle. For buildings across mid-Wales and Shropshire with poor or expensive heating, that winter performance is often what justifies the project.
Inverter-driven plant, properly sized, uses noticeably less energy than oversized fixed-speed equipment — which is where good design pays for itself.
Questions
Yes. Site surveys and written quotations are free, and there is no obligation to proceed.
The same working day or the following one for most jobs. Larger multi-zone projects can take slightly longer because the design work behind them is bigger.
Usually under an hour for a straightforward property. Larger commercial buildings take longer because there is more to measure and more access to check.
Yes. If a smaller system, a different unit type or a repair to what you already have is the better answer, that is what the survey will say.
We are happy to survey and specify independently so you can compare like for like. A written specification makes it obvious whether two quotes cover the same system.
Yes — risk assessments and method statements are issued on request for site inductions, along with our insurance details and F-Gas credentials.
Yes. Phasing, access and out-of-hours working are agreed before we start, and we will coordinate with your main contractor where there is one.
We survey across Welshpool, Shrewsbury, Oswestry, Newtown, Llanidloes, Llandrindod Wells, Aberystwyth and the surrounding mid-Wales and Shropshire villages.
Next step
Tell us about the building and we will attend, assess the heat load and send a free written specification and quotation — same or next working day.
Call 07530 674866Two minutes now, a written price back the same or next working day.